LambdaCalculator Construction calculators
My calculations
Settings

Thermal insulation

Nominal U-value calculator for layers

Nominal R and U for entered homogeneous layers.

Nominal U-value calculator for layers

Layers
Layer 1
m
W/(m·K)
Surface resistance

Nominal homogeneous-layer result only; it excludes bridges, fixings, moisture and design assessment.

Calculated result

Your result will appear here

Enter the measurements, then calculate.

Calculated in this browser.

Continue your calculation

How to use this calculator

Method and boundary

Enter each layer using thickness and design λ or direct R in SI or US. Select the direct R unit in layer mode independently of length preference. Use the product's total R at the selected thickness, not R per inch. Include each layer once and record surface-resistance selection.

Material R = Σlayer R; total R = material R + selected Rsi/Rse; U = 1/total R

Example

A 0.1 m / 0.040 layer plus direct R = 0.5 gives material R = 3. With fixed Rsi 0.13 and Rse 0.04: R = 3.17 m²·K/W and U ≈ 0.315 W/(m²·K).

Surface mode adds fixed 0.13 and 0.04 values rather than selecting them for heat-flow direction or conditions. The model omits inhomogeneities, bridges, fixings, moisture and full standard corrections.

Read guide: Layered U-value: units, surface resistances and model limits

Calculation privacy

Recent activity remembers which calculator and page you used, the language, time and unit system in this browser. It does not save entered values or results.