R-value to U-value calculator

Convert R-value to U-value or U-factor and back. Compare US and SI units, RSI, formulas and worked examples.

Thermal R/U converter

R = thermal resistance · U = thermal transmittance

m²·K/W
Enter the value from the product document in the unit shown.

Use 1/R only within the same unit system. For example, US R-13 equals about RSI 2.289, not RSI 13.

Calculated result

Your result will appear here

Enter the measurements, then calculate.

Calculated in this browser.

How to use this calculator

Method and boundary

Select conversion direction and the R/U unit system first. The entered number must use the displayed input unit; thermal-unit mode is independent of length preference.

Within the same unit system: U = 1/R and R = 1/U

Example

R = 2.5 m²·K/W corresponds to U = 0.4 W/(m²·K) when both describe the same scope.

Unit conversion or taking a reciprocal does not add omitted layers or surface resistances. Insulation R does not thereby become whole-wall U.

Read guide: Lambda values for EPS, XPS and mineral wool

Calculation privacy

Recent stores calculator ID, route ID, locale, time and unit system only.

How do you convert R-value to U-value?

R-value measures thermal resistance; U-value measures thermal transmittance. They are reciprocals for the same material or assembly scope in matching units. A US insulation label does not give the same numerical R-value as SI units.

  • SI R-value (RSI): U [W/(m²·K)] = 1 / R [m²·K/W].
  • US R-value: U-factor [Btu/(h·ft²·°F)] = 1 / R [h·ft²·°F/Btu].
  • US R-value to SI: RSI ≈ R(US) / 5.678263337; U(SI) ≈ 5.678263337 / R(US).

R-13, R-19 and R-30 conversion table

Our own numerical conversion examples. This table does not specify required insulation or the U-value of a complete wall; each R-value must cover the same scope as the U-value being compared.

R-value and corresponding U-value units
R (US)
h·ft²·°F/Btu
RSI
m²·K/W
U (SI)
W/(m²·K)
U-factor (US)
Btu/(h·ft²·°F)
R-132.28940.43680.0769
R-193.34610.29890.0526
R-305.28330.18930.0333
R-386.69220.14940.0263
R-498.62940.11590.0204

R-value and U-value conversion questions

Does R-30 mean a U-value of 0.033?

US R-30 gives a U-factor of about 0.03333 Btu/(h·ft²·°F), but an SI U-value of about 0.18928 W/(m²·K). A value of 0.033 without a unit can therefore give a misleading comparison.

What is the difference between R-value and RSI?

RSI is thermal resistance in m²·K/W. US R-value is usually expressed in h·ft²·°F/Btu. US R-13 is approximately RSI 2.289. Canadian labels can use either notation, so check the unit on your document.

Are U-value and U-factor the same thing?

Both describe thermal transmittance, but their units and tested scope must match. Do not compare the U-factor of a complete window with the R-value of an insulation layer. Select SI or US according to the document.

Can I calculate a whole wall U-value from insulation R-value?

Not by taking the reciprocal of one insulation board's R-value. Total resistance must cover the relevant layers and surface resistances; thermal bridges and non-uniform parts may need a different method. This tool converts a number and does not design an assembly.

Units and conversion factor: NIST, Guide to the SI, Appendix B.9 (thermal insulance and coefficient of heat transfer).