Brick wall
Base wall build-up used for the estimate.
This refinement page estimates how much insulation is needed to reach the target U-value for a brick wall.
Used for quick thermal checks of walls, roofs, and floors.
The refinement example starts from the base wall resistance, subtracts it from the target total resistance, and converts the remaining resistance into thickness.
The table below compares the insulating thickness needed for the most common materials used on this site.
This variant describes an assembly related to a wall. The page focuses on material, thickness, and the resulting U-value. Read the value as a conceptual comparison: it shows the effect of thickness and lambda, but it does not include every junction detail, fixing, or moisture condition.
The insulation material or assumption is an insulation layer. If there is no additional insulation, the result mainly shows the limits of the structural layer itself.
Masonry assemblies need attention at ring beams, lintels, balconies, and foundation junctions. Before using the result for construction decisions, check current product data, local requirements, layer continuity, and possible thermal bridges.
Compare this page with nearby variants rather than reading it in isolation. The most useful set is the no-additional-layer case, a minimum option, and an option with margin for installation error and material tolerance.
If the example covers services, concrete, or heating, use it as a starting point for range checking. Exact sizing still depends on standards, loads, pressures, protective devices, or local execution conditions.
Base wall build-up used for the estimate.
Remaining resistance is translated into insulation thickness.
Target U-value 0.20 W/m²K based on a brick wall reference build-up.
This is a quick reference page for planning. Use the full calculator to verify junctions and detailed layer ordering.
Mineral wool and EPS are shown because they are common search targets and give a fast comparison baseline.
The target resistance is 1 / U. Once the base wall resistance is known, the remaining resistance can be turned into thickness for a chosen insulation material.
For this reference page, mineral wool and EPS are compared side by side so the page stays useful without being empty.
The calculators use visible formulas and explicit unit conversions. Treat the result as a preliminary check, not a complete building design.
See how formulas, unit conversions, rounding, and limitations are handled. Methodology details.